|
DL QuickSpecs
|
DL20
|
|
DL60
|
|
DL80
|
|
DL120
|
|
DL140
|
|
DL145
|
|
DL160
|
|
DL160se
|
|
DL165
|
|
DL180
|
|
DL185
|
|
DL320
|
|
DL325
|
|
DL345
|
|
DL360
|
|
DL365
|
|
DL380
|
|
DL385
|
|
DL388
|
|
DL560
|
|
DL580
|
|
DL585
|
|
DL740
|
|
DL760
|
|
DL785
|
|
DL1000
|
|
|
ML QuickSpecs
|
ML30
|
|
ML110
|
|
ML115
|
|
ML150
|
|
ML310
|
|
ML330
|
|
ML350
|
|
ML370
|
|
ML530
|
|
ML570
|
|
ML750
|
|
|
BL QuickSpecs
|
BL10e
|
|
BL20p
|
|
BL25p
|
|
BL260c
|
|
BL280c
|
|
BL2x220c
|
|
BL30p
|
|
BL35p
|
|
BL40p
|
|
BL420c
|
|
BL45p
|
|
BL460c
|
|
BL465c
|
|
BL480c
|
|
BL495c
|
|
BL60p
|
|
BL620c
|
|
BL660c
|
|
BL680c
|
|
BL685c
|
|
BL860c
|
|
|
SL QuickSpecs
|
SL160z
|
|
SL165z
|
|
SL170s
|
|
SL170z
|
|
SL230s
|
|
SL250s
|
|
SL270s
|
|
SL2x170z
|
|
SL335s
|
|
SL390s
|
|
SL4540
|
|
SL4545
|
|
|
XL QuickSpecs
|
XL170r
|
|
XL190r
|
|
XL220a
|
|
XL230a
|
|
XL730f
|
|
XL740f
|
|
XL750f
|
|
|
CL QuickSpecs
|
CL1850
|
CL1850 G1
| |
CL380
|
CL380 G1
| |
|
|
|
|
|
|
|
Proliant DL145 G2 QuickSpecs |
US QuickSpecs |
|
|
|
|
|
|
|
|
|
Proliant DL145 G2 Overview
HP ProLiant DL145 Generation 2 (G2)
|
1. Access Panel |
2. 500 Watt Power Supply |
3. PCI-X I/O Expansion Assembly with (1) 133MHz
Full Height, Full-Length PCI-X slot which supports PCI Express
with optional riser board and (1) 133MHz Low-Profile, Half-Length
PCI-X Slot. |
4. Memory Bank 1A & 1B, supporting up to 8 GB
PC3200 DDR1 SDRAM |
5. Processor 1 |
6. Processor 2
|
7. Memory Bank 2A & 2B, supporting up
to 8 GB PC3200 DDR1 SDRAM |
|
8. System Fans |
9. Power ON/OFF Button |
10. Front USB Ports |
11. System LEDs |
12. Optional CD or DVD-ROM Drive |
13. Non-Hot Plug SATA OR SCSI Hard
Drive Bay |
14. Non-Hot Plug SATA OR SCSI Hard
Drive Bay |
|
|
|
What's New |
- Supports 1 or 2 AMD Opteron Rev. E processors with 1 GHz HyperTransport
Technology
|
|
At A Glance |
- Processors:
- AMD 8132 Chipset for PCI-X support and NVIDIA nForce Professional
2200 MCP for PCI Express
- DL145 G2 Memory:
- 1 or 2 GB of PC3200 DDR SDRAM running at 400 MHz with Advanced
ECC capabilities standard (depending on model), expandable to 16
GB
- Storage Controller:
- Integrated Dual Broadcom 10/100/1000 5721 NICs (Wake on LAN and
PXE capable)
- Embedded SATA Controller
- Internal Drive Support:
- Support for up to two SATA and or SCSI Non Hot Plug hard drives
- Internal storage capacity of up to 1TB (2 x 500GB non-hot plug
2.5" SATA HDDs), or 292GB (2 x 146GB NHP SCSI HDDs)
- Network Controller:
- Integrated Dual Broadcom 5721 10/100/1000 NICs (Wake on LAN and
PXE capable)
- Expansion Slots:
- Two PCI-X 64-bit/133MHz PCI slots operating at 3.3 volts (one
full-length/full-height, one low-profile); optional PCI Express
x16 in place of full-size slot
- USB Ports:
- Four USB ports (two rear, two front)
- Optical Drives:
- Optional DVD- or CD-ROM drive
- Power Supply:
- 500W Power Supply (Non-Hot Plug, autoswitching)
- Form Factor:
- Management:
- HP ProLiant Lights Out 100i Remote Management standard
- IPMI 2.0 support
- ROM Setup Utility
- Warranty:
- Protected by HP Services, including a one-year, limited warranty,
Parts only 1 year limited Global warranty - Certain restrictions
and exclusions apply.
|
Standard Features
NOTE: For the Standard Features shipped
in the "Factory Integrated Models", please see the "Configuration
Information - Factory Integrated Models" section.
|
Processor
One of the following depending on Model |
AMD Opteron Model 285 (2.6 GHz/1MB)
dual-core processor supporting 1 GHz HyperTransport Technology |
AMD Opteron Model 275 (2.2 GHz/1MB)
dual-core processor supporting 1 GHz HyperTransport Technology |
AMD Opteron Model 252 (2.6 GHz/1MB)
single-core processor supporting 1 GHz HyperTransport Technology |
AMD Opteron Model 248 (2.2 GHz/1MB)
single-core processor supporting 1 GHz HyperTransport Technology |
AMD Opteron Model 246 (2.0 GHz/1MB)
single-core processor supporting 1 GHz HyperTransport Technology |
|
Cache Memory
|
1MB Level 2 cache memory per
core |
|
Upgradeability |
Upgradeable to dual processing |
|
Chipset |
AMD 8132 Chipset for PCI-X support
and NVIDIA nForce Professional 2200 MCP for PCI Express |
|
Memory Protection |
Advanced ECC capabilities |
|
Memory
One of the following depending on Model
|
Type |
PC3200 DDR SDRAM running at
400 MHz |
|
Standard |
1 GB
NOTE: Available with 2.0 & 2.2GHz
single core models. |
(2 x 512 MB) |
2 GB
NOTE: Available with 2.6 single core
models and all dual core models (2.2 & 2.6). |
(2 x 1 GB) |
Maximum |
16 GB |
(8 x 2 GB) |
|
Network
Controller |
Integrated Dual Broadcom 5721
10/100/1000 NICs (Wake on LAN and PXE capable) |
|
Expansion Slots |
Slot # |
Bus Speed |
Hot Plug (Y/N)
|
Voltage/Connector |
Notes |
1 |
64-bit/133MHz PCI-X |
No |
3.3 Volt |
Full length, full
height |
1 |
X16 PCI Express |
No |
3.3 Volt |
Full length, full
height |
2 |
64-bit/133MHz PCI-X |
No |
3.3 Volt |
Low Profile |
NOTE:
For more information regarding PCI-X, please see the following URL:
https://www.hp.com/servers/pci-x. |
NOTE:
All slots can accept qualified universal keyed PCI cards. |
|
Storage
Controller |
Embedded SATA Controller |
|
Storage |
Diskette Drives |
via USB only (optional) |
DVD-ROM |
8x IDE (ATAPI) DVD-ROM drive,
slim (optional) |
CD-ROM |
24x IDE (ATAPI) CD-ROM drive
(optional) |
Hard Drives
|
80-GB SATA (non-hot plug)
36-GB 15,000 rpm, Ultra NHP SCSI Drives (all non-hot plug) |
|
Maximum
Internal Storage
(Depending on model) |
SATA |
1TB |
2 x 500GB |
SCSI |
292GB
|
2
x 146GB |
|
Interfaces |
Parallel
|
None |
Network RJ-45(Ethernet) |
1-Dedicated for HP ProLiant
Lights Out 100i Remote Management |
Pointing Device (Mouse) |
1 |
Graphics/Keyboard |
1/1 |
Serial |
1 |
USB |
4 (two front; two rear)
NOTE: Please see the following
URL for additional information regarding USB support:
https://h18004.www1.hp.com/products/servers/platforms/usb-support.html.
|
Network RJ-45 (Ethernet) |
2 |
|
Graphics |
Integrated NVIDIA GeForce2 GPU
with 16MB DDR video memory |
|
Form
Factor |
Rack Mount (1U) |
|
ProLiant Essentials
Foundation Pack Software |
Optional ProLiant
Essentials Value Packs |
Optional software offerings
that selectively extend the functionality of an Adaptive Infrastructure
to address specific business problems and needs: |
- Intelligent Networking Pack - detects and analyzes network bottlenecks
or broken network linkages and steers traffic to the optimum route based
on network conditions, plus it provides an extra layer of protection.
The virus throttle feature of the solution slows the propagation of
fast spreading virus.
- Rapid Deployment Pack (RDP) is an automated deployment and provisioning
solution for all ProLiant servers. RDP includes the ProLiant Integration
Module featuring ProLiant server pre-configured events for OS installation,
and optimized software drivers, firmware and management agents. Every
RDP disc includes 10-node trial licenses for evaluation purposes. RDP
requires a license for each server deployed and is available for purchase
with HP servers. For more information, visit: https://www.hp.com/servers/rdp.
- Vulnerability and Patch Management Pack - identifies and remediates
software security vulnerabilities due to missing patches as well as
operating system configurations that can be exploited by viruses, worms
and other blended threats.
|
NOTE: Flexible
and volume quantity license kits are available for ProLiant Essentials Value
Packs. Refer to
https://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information.
NOTE: For more information regarding ProLiant Essentials Software,
please see the following URL:
https://www.hp.com/servers/proliantessentials. |
|
Industry Standard
Compliance |
ACPI V2.0 Compliant |
PCI 2.2 Compliant |
PXE Support |
WOL Support |
Microsoft® Logo certifications |
IPMI 2.0 Compliant |
|
Manageability |
HP ProLiant Lights Out 100i
Remote Management integrated standard |
|
Security |
Power-on password |
Setup password |
|
Server Power Cords |
One 10' Highline IEC Power cord
ships standard (for connection to a Power Distribution Unit). Units shipped
in Japan will have a 12' power cord. |
NOTE: Rack models
ship standard with a 10' IEC cable. Localized cables included with geographic
specific models in other world regions |
|
Power
Supply |
500 Watts, auto-switching, PFC
(Power Factor Correcting) |
|
System
Fans |
6 - Non-hot plug, Non-redundant
system fans shipped standard |
|
Rack Airflow Requirements |
Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires
increased cooling efficiency for rack-mounted servers. The 10000 Series
Racks provide enhanced airflow for maximum cooling, allowing these racks
to be fully loaded with servers using the latest processors.
CAUTION: If a third-party rack is
used, observe the following additional requirements to ensure adequate airflow
and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and
rear doors, you must allow 5,350 sq cm (830 square inches) of hole evenly
distributed from top to bottom to permit adequate airflow (equivalent to
the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels
of the rack must be a minimum of 7 cm (2.75 inches)
CAUTION: Always use blanking panels
to fill all remaining empty front panel U-spaces in the rack. This arrangement
ensures proper airflow. Using a rack without blanking panels results in
improper cooling that can lead to thermal damage.
NOTE: For additional information,
refer to the Setup and Installation Guide or the Documentation CD provided
with the server, or to the server documentation located in the Support section
at the following URL: https://h18000.www1.hp.com/products/servers/proliantdl140/index.html
|
|
Telco Rack Support |
Telco Rack Kit:
Support for all 2-post Telco racks requires the use of the standard rack
kit and an additional option kit from Rack Solutions.
https://www.racksolutions.com/hp |
|
HP Factory Express Capability |
HP Factory Express offers configuration,
customization, integration and deployment services for HP servers and storage
products. Customers can choose how their factory solutions are built, tested,
integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking,
installation, complex configuration and design services as well as individual
factory services, such as image loading, asset tagging, and custom packaging.
HP products supported through Factory Express include a wide array of
servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades,
HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA, XP,
rackable tape libraries and configurable network switches.
For more information on Factory Express services for your specific server
model please contact your sales representative or go to https://www.hp.com/go/factory-express.
|
|
HP Enterprise Configurator |
The HP eCo-Enterprise Configurator
now provides factory default racking for our HP hardware portfolio. This
approach is aligned with our strategic direction to meet the needs and expectations
of our valued customers. If you require "custom" rack configuration,
please contact HP's Customer Business Center or an Authorized Partner for
assistance. |
|
Service and Support |
This product is covered by a global limited warranty and supported by
HP Services and a worldwide network of resellers and service providers.
Hardware diagnostic support and repair is available for three years from
date of purchase. Support for software and initial setup is available
for 90 days from date of purchase. Additional support may be covered under
the warranty or available for an additional fee. Enhancements to warranty
services are available through HP Care Pack services or customized service
agreements.
NOTE: Server Warranty includes 1 year
Parts only. Additional information regarding worldwide limited warranty
and technical support is available at: https://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
HP Care Pack services include coverage for the HP branded hardware options
qualified for the server, purchased at the same time or afterward, internal
to the enclosure, as well as 22" and smaller external monitors and
tower UPS options up to 3kVA; these items will be covered at the same
service level and for the same coverage period as the server. Coverage
of UPS Battery is not included, standard warranty terms & conditions
apply. For servers or storage systems installed within a rack, service
also covers all HP qualified rack options installed within the same rack.
HP services provide continuous care and support expertise with committed
response designed to meet your IT and business needs.
To fully capitalizing on your HP ProLiant servers' capabilities requires
a service partner who thoroughly understands your server technology and
systems environment. HP Services, an industry leader in provision of multi
vender support solutions provides a range of support services designed
to meet the varying needs of business. Whether an SMB or large global
corporation HP has a ProLiant server support offer to help you speedily
deploy and maximize system uptime.
Enhanced Care Minimum recommended service support offer designed
to ensure customers have access to expert assistance, whenever they need
it.
- Next Business Day on site coverage, 3 Years
Continuance Care Recommended service, delivering cost-effective
support options designed to extend HP Services committed response and
guaranteed fix times, designed to speed problem identification and resolution.
- 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years
Total Care Highest HP Support service level recommend to help
increase IT performance and availability with comprehensive, integrated
hardware and software services
- 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years
Deployment Services HP Installation and Start Up services designed
to take time, risk, and worry out of the deployment of ProLiant servers
and free customers IT support staff to focus on what they do best,
their business.
- Installation of a ProLiant server as per Data Sheet. To be delivered
on a scheduled basis 8am-5pm, M-F, excl. HP holidays
For a complete listing of service offerings and information visit:
https://www.hp.com/services/proliantservices
https://www.hp.com/go/proliant/carepack
|
HPC Interconnects
NOTE:
High Performance Computing (HPC) interconnect technologies are available
for the DL145 under the Cluster Platform product portfolio. These high-speed
interconnects are fully supported by HP when they are part of these configure
to order clusters. Solutions can be defined with a lot of flexibility with
the help of configuration tools. Please visit the following URL to configure
HPC Clusters with InfiniBand, Gigabit Ethernet or Myrinet Interconnects:
https://www.hp.com/techservers/clusters/ucp/index.html |
|
HPC Interconnects |
InfiniBand
|
PCI-X and PCI-Express adapters |
|
Gigabit Ethernet |
Use embedded ports |
|
Myrinet XP |
PCI-X Rev D and Rev E adapters |
Models
Dual-Core
Models |
ProLiant DL145
G2 2.6GHz /1MB Opteron DC 2GB 80GB NHP SATA
411095-xx1 |
Processor |
AMD Opteron Model 285 (2.6 GHz/1MB)
processor (Dual-Core) |
Cache Memory |
1MB L2 cache per core |
Memory |
2 GB (2 x 1 GB) PC3200 DDR1
SDRAM running at 400 MHz, with Advanced ECC capabilities |
Network Controller |
Integrated Dual Broadcom 5721
10/100/1000 NICs (Wake on LAN and PXE capable) |
Storage Controller |
Embedded SATA Controller |
Hard Drive |
80GB NHP SATA (non-hot plug) |
Internal Storage |
1TB maximum (with optional hard
drive) |
Form Factor |
Rack Mount (1U) |
|
ProLiant DL145
G2 2.6GHz /1MB Opteron DC 2GB 36GB NHP SCSI
411094-xx1
|
Processor |
AMD Opteron Model 285 (2.6 GHz/1MB)
processor (Dual-Core) |
Cache Memory |
1MB L2 cache per core |
Memory |
2 GB (2 x 1 GB) PC3200 DDR1
SDRAM running at 400 MHz, with Advanced ECC capabilities |
Network Controller |
Integrated Dual Broadcom 5721
10/100/1000 NICs (Wake on LAN and PXE capable) |
Storage Controller |
U320 Single Channel PCI-X controller
(in low profile slot) |
Hard Drive |
36GB 15,000 Ultra 320 NHP SCSI |
Internal Storage |
292GB maximum (with optional
hard drive) |
Form Factor |
Rack Mount (1U) |
|
ProLiant DL145
G2 2.2GHz /1MB Opteron DC 2GB 80GB NHP SATA
390846-xx1
| Processor |
AMD Opteron Model 275 (2.2 GHz/1MB)
processor (Dual Core) |
Cache
Memory |
1MB L2 cache per core |
Memory |
2 GB (2 x 1 GB) PC3200 DDR1
SDRAM running at 400 MHz, with Advanced ECC capabilities |
Network Controller |
Integrated Dual Broadcom 5721
10/100/1000 NICs (Wake on LAN and PXE capable) |
Storage
Controller |
Embedded SATA Controller |
Hard
Drive |
80GB NHP SATA (non-hot plug) |
Internal
Storage |
1TB maximum (with optional hard
drive) |
Form
Factor |
Rack Mount (1U) |
|
ProLiant DL145
G2 2.2GHz/1MB Opteron DC 2GB 36GB NHP SCSI
390845-xx1
|
Processor |
AMD Opteron Model 275 (2.2 GHz/1MB)
processor (Dual-Core) |
Cache Memory |
1MB L2 cache per core |
Memory |
2 GB (2 x 1GB) PC3200 DDR1 SDRAM
running at 400 MHz, with Advanced ECC capabilities |
Network Controller |
Integrated Dual Broadcom 5721
10/100/1000 NICs (Wake on LAN and PXE capable) |
Storage Controller |
U320 Single Channel PCI-X controller
(in low profile slot) |
Hard Drive |
36GB
15,000 Ultra 320 NHP SCSI |
Internal Storage |
292GB maximum (with optional
hard drive) |
Form Factor |
Rack Mount (1U) |
|
Single-Core
Models |
ProLiant DL145
G2 2.6GHz/1MB Opteron 2GB 80GB NHP SATA
377888-xx1 |
Processor |
AMD Opteron Model 252 (2.6 GHz/1MB)
processor |
Cache Memory |
1MB L2 cache |
Memory |
2 GB (2 x 1 GB) PC3200 DDR1
SDRAM running at 400 MHz, with Advanced ECC capabilities |
Network Controller |
Integrated Dual Broadcom 5721
10/100/1000 NICs (Wake on LAN and PXE capable) |
Storage Controller |
Embedded SATA Controller |
Hard Drive |
80GB NHP SATA (non-hot plug) |
Internal Storage |
1TB maximum (with optional hard
drive) |
Form Factor |
Rack Mount (1U) |
|
ProLiant DL145
G2 2.6GHz/1MB Opteron 2GB 36GB NHP SCSI
377887-xx1
|
Processor |
AMD Opteron Model 252 (2.6 GHz/1MB)
processor |
Cache
Memory | 1MB L2 cache |
Memory |
2 GB (2 x 1 GB) PC3200 DDR1
SDRAM running at 400 MHz, with Advanced ECC capabilities |
Network Controller |
Integrated Dual Broadcom 5721
10/100/1000 NICs (Wake on LAN and PXE capable) |
Storage
Controller |
U320 Single Channel PCI-X controller
(in low profile slot) |
Hard
Drive |
36GB 15,000 rpm Ultra 320 NHP
SCSI |
Internal
Storage |
292GB maximum (with optional
hard drive) |
Form
Factor | Rack Mount (1U) |
|
ProLiant DL145
G2 2.2GHz/1MB Opteron 1GB 80GB NHP SATA
377886-xx1
|
Processor |
AMD Opteron Model 248 (2.2 GHz/1MB)
processor |
Cache
Memory | 1MB L2 cache |
Memory |
1 GB (2 x 512 MB) PC3200 DDR1
SDRAM running at 400 MHz, with Advanced ECC capabilities |
Network Controller |
Integrated Dual Broadcom 5721
10/100/1000 NICs (Wake on LAN and PXE capable) |
Storage
Controller |
Embedded SATA Controller |
Hard
Drive |
80GB NHP SATA (non-hot plug) |
Internal
Storage |
1TB maximum (with optional hard
drive) |
Form
Factor | Rack Mount (1U) |
|
ProLiant DL145
G2 2.2GHz/1MB Opteron 1GB
36GB NHP SCSI
377885-xx1
|
Processor |
AMD Opteron Model 248 (2.2 GHz/1MB)
processor |
Cache
Memory | 1MB L2 cache |
Memory |
1 GB (2 x 512 MB) PC3200 DDR1
SDRAM running at 400 MHz, with Advanced ECC capabilities |
Network Controller |
Integrated Dual Broadcom 5721
10/100/1000 NICs (Wake on LAN and PXE capable) |
Storage
Controller |
U320 Single Channel PCI-X controller
(in low profile slot) |
Hard
Drive |
36GB 15,000 rpm Ultra 320 NHP
SCSI |
Internal
Storage |
292GB maximum (with optional
hard drive) |
Form
Factor | Rack Mount (1U) |
|
ProLiant DL145
G2 2.0GHz/1MB Opteron 1GB 80GB NHP SATA
377884-xx1
|
Processor |
AMD Opteron Model 246 (2.0 GHz/1MB)
processor |
Cache Memory |
1MB L2 cache |
Memory |
1 GB (2 x 512 MB) PC3200 DDR1
SDRAM running at 400 MHz, with Advanced ECC capabilities |
Network Controller |
Integrated Dual Broadcom 5721
10/100/1000 NICs (Wake on LAN and PXE capable) |
Storage Controller |
Embedded SATA Controller |
Hard Drive |
80GB NHP SATA (non-hot plug) |
Internal Storage |
1TB maximum (with optional hard
drive) |
Form Factor |
Rack Mount (1U) |
|
ProLiant DL145
G2 2.0GHz/1MB Opteron 1GB 36GB NHP SCSI
377883-xx1
|
Processor |
AMD Opteron Model 246 (2.0 GHz/1MB)
processor |
Cache Memory |
1MB L2 cache |
Memory |
1 GB (2 x 512 MB) PC3200 DDR1
SDRAM running at 400 MHz, with Advanced ECC capabilities |
Network Controller |
Integrated Dual Broadcom 5721
10/100/1000 NICs (Wake on LAN and PXE capable) |
Storage Controller |
U320 Single Channel PCI-X controller
(in low profile slot) |
Hard Drive |
36GB 15,000 rpm Ultra 320 NHP
SCSI |
Internal Storage |
292GB maximum (with optional
hard drive) |
Form Factor |
Rack Mount (1U) |
|
Country Code Key |
XX = 00 |
NA |
XX = 29 |
Japan |
XX = 20 |
Brazil |
XX = 37
|
AP |
XX = 42
|
EURO |
XX = AA |
PRC |
Configuration Information - Factory Integrated Models (North America only)
NOTE: For Configure to Order requirements within EMEA region,
please consult local Sales Contact.
NOTE: HP does not allow factory integration of options into standard
models listed above.
Configure-to-order servers must start with a CTO Chassis.
NOTE: This product offering does not support HP Factory Express
Server Configuration Level 1.
NOTE: FIO indicates that this option is a Factory Installable Option.
|
|
Step 1: Base Configuration |
|
SCSI Model |
HP ProLiant DL145 G2 SCSI Rack
Chassis |
378024-405
|
Factory Integrated Model ships
with: |
|
Integrated Dual Broadcom 5721
10/100/1000 NICs (Wake on LAN and PXE capable) |
|
HP U320 Internal SCSI Cable Kit |
|
Two available 64-bit/133MHz PCI-X
slots, including one full-length/full height and one low-profile/half height
slot
NOTE: The low-profile/half height
slot houses the SCSI HBA when installed. |
|
500 Watt power supply |
|
NOTE: Must select
HP Low Profile U320 SCSI HBA, (P/N 390402-B21) in Step 2 when selecting
the SCSI Rack Chassis, (P/N 378024-405)
NOTE: The selection of SCSI Model (P/N 376343-405), requires the
selection of (1) SCSI Controller. Please see Step 3 of this section for
compatible SCSI Controllers.
|
|
SATA Model |
HP ProLiant DL145 G2 SATA Rack
Chassis |
389695-405
|
Factory Integrated Model ships
with: |
|
Integrated Dual Broadcom 5721
10/100/1000 NICs (Wake on LAN and PXE capable) |
|
Embedded SATA Controller |
|
Two available 64-bit/133MHz PCI-X
slots, including one full-length/full height and one low-profile/half height
slot |
|
500 Watt power supply |
|
Rack Mount (1U) |
|
|
Step 2: Choose Required Options
(only one of the following from each list unless otherwise noted) |
Base Processors |
AMD O285 2.6 GHz/1MB DL145 G2
FIO BASE
NOTE: If 2 processors are desired,
select one 411097-B21and one 411097-B21. |
411097-B21
|
AMD O280 2.4 GHz/1MB DL145 FIO
BASE
NOTE: If 2 processors are desired,
select one 399444-B21and one 399444-B21. |
399444-B21
|
AMD O275 2.2 GHz/ 1MB DL145 G2
FIO BASE
NOTE: If 2 processors are desired,
select one 391782-B21and one 391782-B21. |
391782-B21
|
AMD O254 2.8 GHz/1MB DL145 G2
FIO BASE
NOTE: If 2 processors are desired,
select one 396861-B21and one 396861-B21. |
396861-B21
|
AMD O252 2.6 GHz/1MB DL145 G2
FIO BASE
NOTE: If 2 processors are desired,
select one 378690-B21and one 378690-B21. |
|
AMD O248 2.2 GHz/1MB DL145 G2
FIO BASE
NOTE: If 2 processors are desired,
select one 379259-B21and one 379259-B21. |
|
AMD O246 2.0 GHz/ 1MB DL145 G2
FIO BASE
NOTE: If 2 processors are desired,
select one 378755-B21and one 378755-B21. |
|
Base Memory |
1 GB PC3200 DDR1
SDRAM DIMM Memory Kit (2 x 512 MB) |
|
2 GB PC3200 DDR1
SDRAM DIMM Memory Kit (2 x 1 GB) |
|
4 GB PC3200 DDR1
SDRAM DIMM Memory Kit (2 x 2 GB) |
|
Hard Drives |
SATA Non-Hot Plug |
|
HP 80GB 1.5G SATA 7.2K NHP 3.5"
HDD
|
|
HP 160GB 1.5G SATA 7.2K NHP 3.5" HDD
|
|
HP 250GB 1.5G SATA 7.2K NHP 3.5"
HDD
|
|
HP 500GB 1.5G SATA 7.2K NHP 3.5"
HDD, FIO* |
404469-B21
|
NOTE:
* Factory Integrated Only
|
|
U320 SCSI Non-Hot Plug |
|
HP 36GB U320 15K NHP HDD |
|
HP 72GB U320 10K NHP HDD |
|
HP 146GB U320 10K NHP HDD |
|
Storage Controller |
HP Low Profile U320 SCSI HBA,
FIO
NOTE: Must select this HBA when selecting
the SCSI Rack Chassis, (P/N 378024-405) |
390402-B21
|
|
Step 3: Choose Additional Options
for Factory Integration |
NOTE: For additional
options, please refer to the "Options" section below. |
Controllers |
HP Single Channel U320 SCSI Controller |
|
NOTE:
Must choose one of the above listed Controllers when selecting the SCSI
Model (P/N 376343-405) in step 1 of this section. |
|
Options
ProLiant Essentials
Licensing and Packaging
|
ProLiant Essentials Intelligent
Networking Pack Windows Edition and Linux Edition |
|
ProLiant Essentials Intelligent
Networking Pack Windows Edition, Single Server License
NOTE: For use with a single server.
Contains one license with a unique license activation key and documentation.
|
372906-B21
|
ProLiant Essentials Intelligent
Networking Pack Linux Edition, Single Server License .
NOTE: For use with a single server.
Contains one license with a unique license activation key and documentation.
|
436229-B21
|
NOTE: For additional
ProLiant Intelligent Networking Pack License Kits please see the QuickSpecs
at: https://h18000.www1.hp.com/products/quickspecs/12062_div/12062_div.html
https://h18000.www1.hp.com/products/quickspecs/12327_div/12327_div.html |
|
ProLiant Essentials Rapid Deployment
Pack |
|
Rapid Deployment Pack, Single-Server
License
NOTE: This license allows 1 server
to be deployed and managed via RDP. |
267196-B21 |
Rapid Deployment Pack, Single-Server
License (Japan)
NOTE: This license allows 1 server
to be deployed and managed via RDP. |
267196-291 |
NOTE: For additional
ProLiant Essentials Rapid Deployment Pack License Kits please see the QuickSpecs
at: https://h18000.www1.hp.com/products/quickspecs/11053_div/11053_div.html |
|
ProLiant Essentials Vulnerability
and Patch Management Pack |
|
ProLiant Essentials Vulnerability
and Patch Management Pack, Single-Server License |
371645-B21 |
NOTE: For additional
ProLiant Vulnerability and Patch Management Pack License Kits, please see
the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/12111_div/12111_div.html
|
|
NOTE: Flexible
and volume quantity license kits are available for ProLiant Essentials Value
Packs. Refer to https://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information.
NOTE: For more information regarding ProLiant Essentials Software,
please see the following URL: https://www.hp.com/servers/proliantessentials. |
|
|
Processor |
AMD O285 2.6 GHz/1MB Dual-Core
Processor Option Kit
|
411097-B21
|
AMD O280 2.4 GHz/1MB Dual-Core
Processor Option Kit
|
399444-B21
|
AMD O275 2.2 GHz/1MB Dual-Core
Processor Option Kit
|
391782-B21
|
AMD O270 2.0 GHz/1MB Dual-Core
Processor Option Kit |
393300-B21
|
AMD O254 2.8 GHz/1MB Single-Core
Processor Option Kit
|
396861-B21
|
AMD O252 2.6 GHz/1MB Single-Core
Processor Option Kit
|
|
AMD O248 2.2 GHz/1MB Single-Core
Processor Option Kit
|
|
AMD O246 2.0 GHz/1MB Single-Core
Processor Option Kit |
378755-B21 |
|
Hard Drives |
SATA - Non-Hot Plug |
|
HP 80GB 1.5G SATA 7.2K NHP 3.5"
HDD
|
|
HP 160GB 1.5G SATA 7.2K NHP 3.5"
HDD
|
|
HP 250GB 1.5G SATA 7.2K NHP 3.5"
HDD |
411276-B21 |
NOTE: When purchasing
systems with the 500GB NHP SATA drives, please reference the Configuration
Information Section of this QuickSpecs to order via Configuration to Order. |
|
U320 SCSI - Not-Hot Plug |
|
HP 36GB U320 15K NHP HDD |
357012-B21 |
HP 72GB U320 10K NHP HDD |
332751-B21 |
HP 146GB U320 10K NHP HDD |
356990-B21 |
|
Optical Drives |
DVD-ROM Drive |
|
CD-ROM Drive |
349046-B21
|
Multibay II DVD/CD-RW Combo Drive
NOTE: When purchasing the Multibay
II DVD/CD-RW Combo Drive, (PN PA850A), the USB 2.0 Multibay II Cradle (PN
PA509A) is required.
|
PA850A
|
USB 2.0 Multibay II Cradle , External
NOTE: When purchasing the Multibay
II DVD/CD-RW Combo Drive (P/N 850A), the USB 2.0 Multibay II Cradle (P/N
PA509A) is required.
|
PA509A
|
|
Storage Controllers
and options |
HP U320 Internal SCSI Cable Kit |
385749-B21
|
64-Bit/133-MHz Single Channel
Ultra320 SCSI HBA G2 |
|
HP 8 Internal Port SAS HBA with
RAID
NOTE: For use with SATA drives only
|
|
HP SATA/SAS 1U Cable Kit
NOTE: For use with SATA drives only
|
|
HP PL 100 SCSI RAID Controller |
|
HP PCI Express Riser Board Kit |
378841-B21 |
|
Communications |
HP NC150T PCI 4-port Gigabit Combo
Switch Adapter |
367132-B21 |
HP NC310F PCI-X 1000SX Gigabit
Server Adapter |
368169-B21 |
HP NC320T PCI Express Gigabit
Server Adapter |
367047-B21 |
HP NC340T PCI-X Quad-Port Gigabit
Server Adapter |
391661-B21 |
HP NC360T PCI Express Dual Port
Gigabit Server Adapter |
412648-B21 |
HP NC370F PCI-X Multifunction
Gigabit Server Adapter |
374193-B22 |
HP NC370T PCI-X Single Port Multifunction
Gigabit Server Adapter |
374191-B22 |
HP NC373F PCI Express Multifunction
Gigabit Server Adapter |
394793-B21 |
HP NC373T PCI Express Multifunction
Gigabit Server Adapter |
394791-B21 |
HP NC380T PCI Express Dual Port
Multifunction Gigabit Server Adapter |
394795-B21 |
HP NC510F PCIe 10 Gigabit Server
Adapter
NOTE: A minimum of 1 gigabyte (1
GB) of server memory is required per each NC510F adapter. |
414126-B21 |
HP NC510C PCIe 10 Gigabit Server
Adapter
NOTE: A minimum of 1 gigabyte (1
GB) of server memory is required per each NC510C adapter. |
414129-B21 |
HP NC1020 PCI Single Gigabit Server
Adapter |
353377-B21 |
HP NC7170 PCI-X Dual Port Gigabit
Server Adapter (full height) |
313881-B21 |
HP NC7170 PCI-X Dual Port, Low
Profile Gigabit Server Adapter |
383738-B21 |
HP NC7771 PCI-X Single Gigabit
Server Adapter |
290563-B21 |
NOTE:
A minimum of 1 GB of memory per port is required for NC370x adapters, with
a maximum of two NC370x ports permitted in a server. |
|
NOTE: For HPC
interconnect adapters please refer to the HPC Interconnect section below. |
|
|
Rack Kits |
1U Cable Management Arm
NOTE: Package contains two cable
management arms.
|
365403-B21 |
|
Tape Drives |
NOTE: A separate
SCSI Controller is required for connecting SCSI tape drives to this server. |
|
NOTE: The following
tape drives are recommended for use with this HP ProLiant server. Additional
HP tape drives are supported. For a complete listing of HP tape drive offerings
supported with this HP ProLiant server, visit: https://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html |
|
USB Tape Drives |
|
HP StorageWorks DAT 24 USB External
Tape Drive, (Carbonite) |
DW070A |
HP StorageWorks DAT 40 USB External
Tape Drive, (Carbonite) |
DW023A |
HP StorageWorks DAT 72 USB External
Tape Drive, (Carbonite) |
DW027A |
DAT External Tape Drives |
|
HP StorageWorks DAT 40 SCSI External
Tape Drive (Carbon) |
C5687D |
HP StorageWorks DAT 72 SCSI External
Tape Drive (Carbon) |
Q1523B |
Ultrium External Tape Drives |
|
HP StorageWorks Ultrium 232 External
Tape Drive (Carbonite) |
DW065B |
Rack-Mount Tape Drive |
|
HP StorageWorks 1U Rack-mount
kit
NOTE: The 1U Rack-mount Kit (PN A7445A)
can support up to (2) half-height tape drives and compatible with multiple
Single-Ended and LVD SCSI tape drives including the DAT 24, DAT 40, DAT
72, DLT VS80, DLT VS160, Ultrium 215, Ultrium 232 and Ultrium 448 tape drives.
|
A7445B |
1U USB Cable Option Kit
NOTE: Converts a 1U SCSI rack-mount
kit to a USB interface to support the USB tape drives. |
396114-B21 |
NOTE: When attaching
to an external tape drive, autoloader or jukebox, you must also purchase
an HBA |
|
NOTE: For a complete
listing of HP tape drive offerings supported with the DL145 G2, visit https://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html |
|
|
StorageWorks Options |
NOTE:
The following is a list of all Fibre Channel Host Bus Adapters for Windows
and Linux. For detailed compatibility information please see: https://h18006.www1.hp.com/storage/saninfrastructure/hba.html
|
|
HP StorageWorks FC2142SR 4Gb PCI-e
HBA |
|
HP StorageWorks FC2242SR Dual
Channel 4 Gb PCI-e HBA
|
|
HP StorageWorks FC1142SR 4Gb PCI-e
HBA |
|
HP StorageWorks FC1242SR Dual
Channel 4 Gb PCI-e HBA |
|
HP StorageWorks FC2143 4Gb PCI-X
2.0 - to Fibre Channel HBA
|
|
HP StorageWorks FC2243 Dual Channel
4Gb PCI-X 2.0 HBA |
|
|
HP Data Protector
Express Software |
HP DP Express Backup Server Upgrade
for ProLiant Software |
BB117AP
|
HP DP Express Package for Microsoft
Small Business Server
|
BB118AA
|
NOTE: Please see
the HP Data Protector Express QuickSpecs for additional information regarding
the purchase of HP Data Protector Express software: https://h18000.www1.hp.com/products/quickspecs/12337_div/12337_div.html
(Worldwide)
NOTE: To obtain a free licensed copy of HP Data Protector Express
for ProLiant edition software, please visit the "Protect Your Data"
link accessible from your ProLiant server's System Management Homepage (SMH)
software (SmartStart 7.5 or later).
|
|
|
USB Options |
HP USB 2-Button Optical Scroll
Mouse (Carbonite/Silver) |
|
USB 1.44-MB External Diskette
Drive |
DC141B
|
HP USB 04 Standard Keyboard |
DT528A#xxx
|
USB 2.0 4-port HUB |
DG954A
|
HP 1GB Drive Key II USB
2.0 Flash Drive |
AG382AA
|
HP 512MB DriveKey II USB
Flash Drive |
ED516AA
|
128MB HP Drive Key (USB 2.0) |
DQ819B
|
256MB HP Drive Key II (USB 2.0) |
PH657A
|
|
HP KVM Switch Options |
HP 1x4 Server Console Switch
|
AF611A |
HP PS2 Server Console Cable, 6
foot, 2-Pack |
AF612A |
HP USB Server Console Cable, 6
foot, 2-Pack
NOTE: required for supporting USB
peripherals. |
AF613A |
NOTE:
For additional information regarding KVM switches, Serial Console servers,
rack mount monitors, keyboards and all related options please see the following
URL: https://www.hp.com/go/kvm |
|
|
HP Serial Console
Server Options |
HP 16 Port Serial Console Server
(worldwide) |
AF101A |
HP 48 Port Serial Console Server
(worldwide) |
AF102A |
Serial Adapter, RJ45-D89 DCE Female,
1-pack |
AF103A |
Serial Adapter, RJ45-D89 DCE Female,
8-pack |
AF110A |
NOTE: Cat5e cables
are required to connect Interface Adapters to Console Switches. Cat5e cables
can be found at the following URL: https://www.hp.com/go/kvm |
|
2x1x16 IP Console Switch with
Virtual Media |
AF601A |
4x1x16 IP Console Switch with
Virtual Media |
AF602A |
2x16 Server Console Switch with
Virtual Media |
AF600A |
PS/2 Virtual Media Interface Adapter,
1 pack
NOTE: Requires PS/2 and one USB port
on server. |
AF604A |
NOTE: For additional
information regarding KVM switches, Serial Console servers, rack mount monitors,
keyboards and all related options please see the following URL: https://www.hp.com/go/kvm |
|
Service and Support, HP Care Pack, and Warranty Information
Service
and Support Offerings (HP Care Pack Services) |
Hardware Services 4-Hour On-site
Service |
|
13-Hour x 5-Day Coverage, 3 Years,
Electronic |
U9509E
|
24-Hour x 7-Day Coverage, 3 Years,
Electronic |
U9510E
|
Hardware Services Next Business
Day On-Site Service |
|
9-Hour x 5-Day Coverage, 3 Years,
Electronic
|
U9508E
|
Hardware Services 6-Hour Call
to Repair On-Site Service |
|
6-Hour Call to Repair, On-site
Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
U9511E
|
Hardware Installation, Electronic |
U9520E
|
NOTE: For more
information, customer/resellers can contact https://www.hp.com/services/carepack. |
|
Memory
NOTE:
Memory configurations listed do not apply to "Factory Integrated Models". |
HP ProLiant DL145
G2 Single Processor Models |
Standard Memory
1 GB (2 x 512 MB) or 2 GB (2 x 1 GB) of PC3200 DDR1 SDRAM running at 400
MHz, with Advanced ECC capabilities Memory installed (depending on model).
Maximum Memory
Up to 16 GB of memory is available with the removal of the standard 512
MB or 1 GB of memory and the optional installation of 2 GB PC3200 Registered
ECC DDR1 SDRAM DIMM Memory kits. |
|
Memory Options
|
The server provides double data
rate (DDR) synchronous dynamic RAM (SDRAM) that can improve memory clock
speed to at least 400-MHz. It activates output on both the rising and falling
edge of the system clock rather than on just the rising edge, potentially
doubling output. The server features the following advanced memory technologies: |
- Support for up to 16 GB of industry-standard PC3200 registered ECC
DDR1 SDRAM memory
- Dual-Channel Memory Architecture
|
Memory Guidelines
|
- Bank 1A must always be populated.
- DIMMs must be installed in pairs and starting at the bank farthest
from the processor. Populate the SMALLEST DIMMs first.
- If only installing 1 GB DIMMs, ensure that the Dual Rank DIMMs are
installed closest to the processor. Dual Rank can be determined by looking
for the "2R" or "2Rx8" wording on the label of the
DIMM.
- All DIMMs in a bank must have the same part number.
- DIMMs on different banks can be of different sizes.
- Processor 2 must be installed before banks 2A and 2B are populated.
- If processor 2 is installed, it is recommended that bank 2A be populated
before populating bank 1B.
- For optimum performance it is recommended that a minimum of banks
1A and 1B be populated in a 2P configuration.
|
NOTE: Chart does
not represent all possible memory configurations. |
DL145 G2 Memory
|
Slot |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
Standard
(1 GB)
|
512 MB |
512 MB |
Empty |
Empty |
Empty |
Empty |
Empty |
Empty |
Standard (2
GB) |
1 GB |
1 GB |
Empty |
Empty |
Empty |
Empty |
Empty |
Empty |
Maximum (16 GB) |
2 GB |
2 GB |
2 GB |
2 GB |
2 GB |
2 GB |
2 GB |
2 GB |
Following are memory options available from HP:
|
|
1 GB Advanced ECC PC3200 DDR1 SDRAM DIMM Memory Kit (2 x 512 MB)
|
376638-B21 |
2 GB Advanced ECC PC3200 DDR1 SDRAM DIMM Memory Kit (2 x 1 GB)
|
376639-B21 |
4 GB Advanced ECC PC3200 DDR1 SDRAM DIMM Memory Kit (2 x 2 GB)
|
379300-B21 |
Storage
|
1 |
Two 1" Non-Hot Plug SATA
or SCSI Hard Drive Bays |
2 |
Optional CD-ROM or DVD drive |
3 |
Power On/Off |
|
Number of drive positions to
match table below. |
Drive Support |
|
Removable
Media |
|
|
|
|
Quantity
Supported |
Position
Supported |
Controller |
DVD-ROM Drive |
Up to 1 |
2
|
8x IDE (ATAPI) DVD-ROM drive,
slim (optional) |
CD-ROM Drive |
Up to 1 |
2 |
24x IDE (ATAPI) CD-ROM drive
(optional) |
Multibay II DVD/CD-RW Combo Drive
|
Up to 1 |
2 |
24x IDE (ATAPI) CD-ROM drive
(optional) |
NOTE: When purchasing
the Multibay II DVD/CD-RW Combo Drive, (PN PA850A), the USB 2.0 Multibay
II Cradle (PN PA509A) is required. |
|
Hard Drives (SCSI Models
only) |
Ultra320 SCSI |
|
Quantity
Supported |
Position
Supported |
Controller |
36GB
72GB
146GB |
Up to 2 |
1 |
U320 Single Channel PCI-X controller
(in low profile slot) |
|
Hard Drives (SATA Models)
|
7,200 rpm SATA |
|
Quantity
Supported |
Position
Supported |
Controller |
80GB
160GB
250GB
500GB* |
Up to 2 |
1 |
Embedded SATA Controller |
NOTE: * Available
via CTO only. |
|
Maximum Storage Capacity
SCSI Models |
Internal |
292GB (2 x 146GB
SCSI hard drives) |
Total |
292GB (2 x 146GB
SCSI hard drives) |
Maximum Storage Capacity
SATA Models |
Internal |
500GB (2 x 250GB
SATA hard drives) |
Total |
500GB (2 x 250GB
SATA hard drives) or
1TB (2 x 500GB SATA drives via CTO only) |
|
For supported tape drive offerings
for this ProLiant server see the following: |
|
Quantity
Supported
|
Position
Supported
|
Controller |
HP StorageWorks Tape Drives,
USB External
DAT 24 USB
DAT 40 USB
DAT 72 USB |
1
|
External
|
USB 2.0 port
|
|
|
|
|
HP StorageWorks Tape Drives,
External
Ultrium 232
DAT 40
DAT 72 |
1 per SCSI channel
|
External
|
64-Bit/133MHz Dual Channel Ultra320
SCSI Adapter
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
|
|
|
|
HP StorageWorks Rack-mount
Tape Drive Enclosures
1U Rack-Mount Kit |
1 per SCSI channel
|
External
|
64-Bit/133MHz Dual Channel Ultra320
SCSI Adapter
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
Power Specifications
Spare Kit |
389322-001 |
Operational Input Voltage Range
(Vrms)
|
90Vac to 264Vac full range at
25oC ambient |
Frequency Range (Nominal) (Hz)
|
47 Hz to 63 Hz |
Power Output |
500W Nominal |
Power Cords (Nema 5-15P to IEC320-C13) |
Standard Power Cord Part Number
(US) |
307348-B21 |
Optional Power Cord Part Number
(US) |
307372-001 |
Quickspecs
System Unit |
Dimensions (HxWxD) |
1.70 x 16.78 x 26.75
in (4.32 x 42.62 x 67.95 cm) |
Weight (approximate; fully
configured) |
35 lb (15.87 kg) |
|
Input Requirements
(per power supply) |
Range Input Voltage |
90 to 140 VAC/180 to 264 VAC |
|
Normal Line Voltage |
115 or 230 VAC |
Line Frequency |
47 to 63 Hz |
|
Rated Input Current load |
7.1A at 115VAC, 3.6A
at 230VAC |
BTU Rating |
BTU-Hr (max configuration) |
2371 |
Power Supply Output Power
(per power supply) |
Rated Steady-State Power |
500W |
Temperature Range |
Operating |
50° to 93° F (10°
to 35° C) |
|
Shipping |
-40° to 140° F (-40°
to 60° C) |
Relative Humidity
(non-condensing)
|
Operating |
10% to 80% |
Non-operating |
10% to 95% |
Acoustic Noise |
Idle (Fixed Disk Drives
Spinning)
|
|
L WAd (BELS)
|
6.31 |
Operating
(Random Seeks to Fixed Disks) |
|
L WAd (BELS)
|
6.32 |
NOTE: All temperature
ratings shown are for sea level. An altitude derating of 1.8° F per
1,000 ft (1° C per 304.8 m) to 10,000 ft (3048 m) is applicable. No
direct sunlight allowed. Upper operating limit is 10,000 ft (3048 m) or
70 Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9144 m) or 30.3KPa/4.4
psia. System performance may be reduced if operating with a fan fault or
above 30° C.
NOTE: Storage maximum humidity of 90% is based on a maximum temperature
of 113° F (45° C).
Altitude maximum for storage corresponds to a pressure minimum of 70 KPa. |
|
Non-Hot Plug SATA Hard
Drives |
80-GB 7.2K
383410-B21 |
Capacity |
80027 MB |
Height |
1.028 in (2.61 cm) |
Width |
4.0 in (10.16 cm) |
Interface |
SATA 100 |
Transfer Rate Synchronous
(Maximum) |
100 MB/s |
Seek Time (typical
reads, including settling) |
Single Track |
|
Average |
|
|
Full-Stroke |
|
|
Rotational Speed |
|
Physical Configuration |
Bytes/Sector |
|
|
Logical Blocks |
|
Operating Temperature |
41° to 131°
F (5° to 55° C) |
|
Non-Hot Plug U320 SCSI
Hard Drive |
36.4-GB 15K
357012-B21 |
Capacity |
36419.2 MB |
Height |
1.0 in (2.54 cm) |
Width |
4.0 in (10.16 cm) |
Interface |
Ultra320 SCSI |
Seek Time (typical
reads, including settling) |
Single Track |
0.4 ms |
Average |
3.8 ms |
Full-Stroke |
8ms |
Rotational Speed |
15,000 rpm |
Physical Configuration |
Bytes/Sector |
512 |
|
Logical Blocks |
71,132,000 |
Operating Temperature |
50° to 95° F
(10° to 35° C) |
|
Embedded SATA Controller |
Drives Supported |
Up to 2 SATA devices
|
Channels |
2 (SATA Drives) |
Storage Capacity |
1 TB internal storage |
Data Transfer Method |
32-bit/33-MHz PCI
bus-master |
Maximum SATA Channel Transfer
Rate |
100 MB/s per channel |
Maximum Transfer Rate per PCI
Bus (peak) |
266 MB/s per channel |
Protocols |
SATA |
PIO Mode[0-4] |
Cable |
SATA |
Internal ATA Connectors |
Two SATA Connectors
(primary and secondary) |
|
64-Bit/133-MHz Single
Channel Ultra320 SCSI HBA G2
(SCSI Model Standard) 374654-B21 |
Drives Supported |
Up to 14 SCSI devices (only supports
2 internal SCSI drives on DL145 G2) |
Channels |
1 |
Storage Capacity |
292 GB internal storage |
Data Transfer Method |
64-bit/133-MHz PCI-X bus-master |
Maximum Host Bus Transfer Rate |
532 MB/s per channel |
Maximum SCSI Transfer Rate |
320 MB/s per channel |
Protocols |
Ultra320 SCSI
Ultra3 SCSI
Wide Ultra2 SCSI
Ultra SCSI |
External SCSI Connector |
One 68-Pin VHDCI connectors |
Internal SCSI Connector |
HP U320 Internal SCSI Cable Kit
(See Storage Controller and I/O Options) |
|
Integrated Dual Broadcom
5721 10/100/1000 NICs (Wake on LAN and PXE capable) |
Network Interface |
10Base-T/100Base-TX/1000Base-TX |
Compatibility |
IEEE 802.3 10Base-T |
IEEE 802.3 1000Base-T |
IEEE 802.3 100Base-TX |
Data Transfer Method |
64-bit, 133MHz PCI(X)1.0 |
Network Transfer
Rate |
10Base-T (Half-Duplex) |
10 Mb/s |
10Base-T (Full-Duplex) |
20 Mb/s |
100Base-TX (Half-Duplex) |
100 Mb/s |
100Base-TX (Full-Duplex) |
200 Mb/s |
1000Base-TX (Half and Full-Duplex) |
2000 Mb/s |
Connector |
RJ-45 |
|
Cable Support |
10Base-T |
Categories 3, 4 or 5
UTP; up to 328 ft (100 m) |
10/100/1000Base-TX |
Category 5 UTP (2 Pair);
up to 328 ft (100 m) |
|
|